Skip to content

Tonearm and cartridge resonance: mass, compliance and the safe range

The arm and the cartridge form a mass-spring system with a low natural frequency. Enter the masses and the cartridge's compliance: the tool computes the resonance as a range (compliance and mass have tolerances), tells you which zone it falls in and what compliance or how many grams you would need to reach 8–11 Hz.

Calculator

The masses

g
g
g
g

The arm's effective mass comes from the maker; weigh the headshell separately if it is not fixed. Weigh the screws.

The cartridge's compliance

cu (10⁻⁶ cm/dyne)
Specified at

1 cu = 10⁻⁶ cm/dyne = 1 µm/mN (not µm/N). The formula needs the value at 10 Hz; catalogues often give it at 100 Hz.

%

How uncertain the mass and compliance are (±). The default is a project choice.

Result

Resonance

8.3 Hz

between 7.2 and 9.7 Hz

central estimate

Total mass

18.5 g

Compliance at 10 Hz used

17.0–23.0 cu

Ideal. The resonance falls in the ideal zone (8–11 Hz). The range crosses zones (from “Acceptable, borderline” to “Ideal”): with these tolerances it cannot be said for certain.

The frequency on the scale

46810121416

Green: 8–11 Hz; yellow: 7–8 and 11–12; red: outside. The bar is the range, the dot the central estimate.

468101214165101520253035404550gHz
20.0 cu8 Hz11 Hz
What would change it

What it would take to reach the 8–11 Hz target

Compliance (at 10 Hz) for your mass

  • at 8 Hz: 21.4 cu
  • at 10 Hz: 13.7 cu
  • at 11 Hz: 11.3 cu

Total mass for your compliance

  • at 8 Hz: 19.8 g
  • at 10 Hz: 12.7 g
  • at 11 Hz: 10.5 g

For 10 Hz you would remove 5.8 g.

Mass changes with a heavier or lighter headshell, a heavier cartridge or weights; compliance does not change, you choose another cartridge.

The ideas behind the controls

A new cartridge on an old arm
Before buying, enter the compliance (at 10 Hz) and the masses: see whether the range lands in 8–11 Hz.
A heavier headshell
If the resonance comes out too high, a heavier headshell lowers it; the tool tells you how many grams.
Compliance at 100 Hz
If catalogues give only the 100 Hz value, use the range: not a single number.

Common mistakes

  • Treating 100 Hz as 10 Hz: the same cartridge has almost twice the compliance at 10 Hz.
  • Forgetting the headshell and the screws in the total mass.
  • Taking a verdict from a single number: mass and compliance have tolerances of tens of percent.

What this tool cannot tell you

  • The zones (8–11 ideal, 7–12 acceptable) are a project guideline; sources differ slightly, many say 8–12 Hz.
  • The 100 Hz to 10 Hz conversion (1.5–2) is a rule of thumb, not a measurement; real compliance varies with the cartridge and the temperature.
  • The arm's effective mass is only as good as the maker's measurement; some arms do not publish it.
  • Damping, the cable and the counterweight are not modelled, only the basic mass-spring system.

Where the formulas come from

  • The mass-spring system: f = 1 / (2π√(M·C)) — The standard formula; with M in grams and C in cu it becomes 1000 / (2π√(M·C)) Hz.
  • Common guidance for arm–cartridge resonance — The ideal/acceptable zones are the project's; sources do not agree exactly.

Frequently asked questions

Why 8–11 Hz?

Below about 7 Hz the system reacts to record warps; above about 12 Hz it approaches the bass in the recording. The exact values differ between sources.

What is a cu?

The compliance unit: 10⁻⁶ cm/dyne, equal to 1 µm/mN.

Why a range?

The specified dynamic compliance and the effective mass are known with wide tolerances; a single number would look more certain than it is.

Tonearm and cartridge resonance: mass, compliance and the safe range · Strunin